打開(kāi)文本圖片集

[摘 要]對(duì)于350 MW超臨界循環(huán)流化床(CFB)鍋爐調(diào)試過(guò)程中點(diǎn)火啟動(dòng)出現(xiàn)的問(wèn)題,根據(jù)問(wèn)題產(chǎn)生原因,提出了調(diào)整點(diǎn)火風(fēng)道結(jié)構(gòu)、適當(dāng)?shù)販p少啟動(dòng)床厚度、控制鍋爐總風(fēng)量等相關(guān)對(duì)策。

[關(guān)鍵詞]超臨界CFB;點(diǎn)火啟動(dòng);優(yōu)化措施

[中圖分類號(hào)]TM621.2 [文獻(xiàn)標(biāo)志碼]A [文章編號(hào)]1001–523X(2022)07–0051–03

The Unit Start-up Optimization of 350 MW Supercritical Circulating Fluidized Bed Was Discussed

Hao Zong-rui

[Abstract]For the ignition and start-up problems of the first 350 MW supercritical circulating fluidized bed (CFB) boiler developed in the world, according to the causes of the problems, relevant countermeasures were put forward, such as adjusting the ignition air duct structure, appropriately reducing the thickness of the starting bed, and controlling the total air volume of the boiler.

[Keywords]supercritical CFB; Ignition start; Optimization measures